Progressive damage FEA of a Type III COPV in Abaqus, custom Hashin failure UMAT (Intel Fortran) for T700/CFRP overwrap, Al 6061-T6 liner, Ti-6Al-4V boss, cohesive zone interface, 18,539 hex elements, four pressure regimes from 52.5 MPa proof load to 2500 MPa material limit investigation.