-
Precise $^{136}$Xe Double Beta Decay Measurement in PandaX-4T with Implications on the Nuclear Matrix Elements and Majorons
Authors:
PandaX Collaboration,
Zhe Yuan,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Manna Deng,
Yingjie Fan,
Deqing Fang,
Xuanye Fu,
Zhixing Gao,
Yujie Ge,
Lisheng Geng,
Karl Giboni,
Xunan Guo,
Xuyuan Guo,
Zichao Guo,
Chencheng Han,
Ke Han,
Changda He,
Jinrong He,
Houqi Huang,
Junting Huang
, et al. (89 additional authors not shown)
Abstract:
The continuous spectrum of double beta decay ($ββ$) provides a sensitive probe to test the predictions of the standard model and to search for signatures of new physics beyond it. We present a comprehensive analysis of the $^{136}$Xe $ββ$ spectrum utilizing $39.1 \pm 0.7~\textrm{kg}\cdot\textrm{yr}$ of $^{136}$Xe exposure from the PandaX-4T experiment. The analysis yields the most precise measurem…
▽ More
The continuous spectrum of double beta decay ($ββ$) provides a sensitive probe to test the predictions of the standard model and to search for signatures of new physics beyond it. We present a comprehensive analysis of the $^{136}$Xe $ββ$ spectrum utilizing $39.1 \pm 0.7~\textrm{kg}\cdot\textrm{yr}$ of $^{136}$Xe exposure from the PandaX-4T experiment. The analysis yields the most precise measurement to date of the $^{136}$Xe two-neutrino double beta decay ($2νββ$) half-life, $(2.14 \pm 0.05) \times 10^{21}$ years, the uncertainty of which is reduced by a factor of 2 compared to our previous result. We measure the parameter $ξ_{31}^{2ν}$, defined as the ratio between the subleading and leading components of the $^{136}$Xe $2νββ$ nuclear matrix element, to be $0.59^{+0.41}_{-0.38}$, which is consistent with theoretical predictions. We also search for Majoron-emitting modes of $^{136}$Xe $ββ$, establishing the most stringent limit for the spectral index $n=7$.
△ Less
Submitted 9 April, 2026; v1 submitted 4 December, 2025;
originally announced December 2025.
-
Experimental study of the reaction $Ξ^{0}n\rightarrowΛΛX$ using $Ξ^{0}$-nucleus scattering
Authors:
BESIII Collaboration,
M. Ablikim,
M. N. Achasov,
P. Adlarson,
X. C. Ai,
R. Aliberti,
A. Amoroso,
Q. An,
Y. Bai,
O. Bakina,
Y. Ban,
H. -R. Bao,
V. Batozskaya,
K. Begzsuren,
N. Berger,
M. Berlowski,
M. Bertani,
D. Bettoni,
F. Bianchi,
E. Bianco,
A. Bortone,
I. Boyko,
R. A. Briere,
A. Brueggemann,
H. Cai
, et al. (707 additional authors not shown)
Abstract:
Using $(10087\pm44)\times10^{6}$$J/ψ$ events collected with the BESIII detector operating at the BEPCII storage ring in $2009$, $2012$, $2018$, and $2019$, we perform a search for the reaction $Ξ^0n\rightarrowΛΛX$, where $X$ denotes any additional final particles. Given the highly suppressed phase space for producing extra pions, the $X$ consists of either nothing or a photon, corresponding to the…
▽ More
Using $(10087\pm44)\times10^{6}$$J/ψ$ events collected with the BESIII detector operating at the BEPCII storage ring in $2009$, $2012$, $2018$, and $2019$, we perform a search for the reaction $Ξ^0n\rightarrowΛΛX$, where $X$ denotes any additional final particles. Given the highly suppressed phase space for producing extra pions, the $X$ consists of either nothing or a photon, corresponding to the processes $Ξ^0 n \rightarrow ΛΛ$ and $Ξ^{0}n\rightarrowΛΣ^0\rightarrowΛΛγ$. The $Ξ^0$ comes from the decay of $J/ψ\rightarrowΞ^0\barΞ^0$, while the neutron originates from material of the beam pipe. A signal is observed for the first time with a statistical significance of 6.4$σ$. The cross section for the reaction $Ξ^0+{^9\rm{Be}}\rightarrowΛ+Λ+X$ is measured to be $(43.6\pm10.5_{\text{stat}}\pm11.1_{\text{syst}})$ mb at $P_{Ξ^0}\approx0.818$ GeV/$c$, where the first uncertainty is statistical and the second systematic. No significant $H$-dibaryon signal is observed in the $ΛΛ$ final state.
△ Less
Submitted 26 February, 2026; v1 submitted 4 December, 2025;
originally announced December 2025.
-
Tomographic beta-gamma spectroscopy of nuclear beta decay
Authors:
PandaX Collaboration,
Zhe Yuan,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Manna Deng,
Yingjie Fan,
Deqing Fang,
Xuanye Fu,
Zhixing Gao,
Yujie Ge,
Lisheng Geng,
Karl Giboni,
Xunan Guo,
Xuyuan Guo,
Zichao Guo,
Chencheng Han,
Ke Han,
Changda He,
Jinrong He,
Houqi Huang,
Junting Huang
, et al. (89 additional authors not shown)
Abstract:
Nuclear $β$ decay, a sensitive probe of nuclear structure and weak interactions, has become a precision test bed for physics beyond the Standard Model, driven by recent advances in spectrometric techniques. Here we introduce tomographic $β$-$γ$ spectroscopy (TBGS) of nuclear $β$ decay, a method that detects the energies of $β$, $γ$, and internal conversion electrons while simultaneously reconstruc…
▽ More
Nuclear $β$ decay, a sensitive probe of nuclear structure and weak interactions, has become a precision test bed for physics beyond the Standard Model, driven by recent advances in spectrometric techniques. Here we introduce tomographic $β$-$γ$ spectroscopy (TBGS) of nuclear $β$ decay, a method that detects the energies of $β$, $γ$, and internal conversion electrons while simultaneously reconstructing the energy deposition vertices. Using the PandaX-4T detector operated as a TBGS, we obtain a precise and unbiased decay scheme of $^{214}$Pb, a key background isotope in searches for dark matter and Majorana neutrinos. For the first time, transitions of $^{214}$Pb to both the ground and excited states of $^{214}$Bi are measured concurrently, revealing discrepancies in branching ratios of up to 4.7$σ$ relative to previous evaluations. Combined with state-of-the-art theoretical spectral-shape calculations, these results establish a new benchmark for background modelling in rare-event searches and highlight the potential of TBGS as a versatile tool for fundamental physics and nuclear applications.
△ Less
Submitted 29 November, 2025; v1 submitted 28 October, 2025;
originally announced October 2025.
-
Precise Measurement of $^{216}$Po Half-life with Exact Parent-daughter Pairing in PandaX-4T
Authors:
PandaX Collaboration,
Chenxiang Li,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Xiangyi Cui,
Manna Deng,
Yingjie Fan,
Deqing Fang,
Xuanye Fu,
Zhixing Gao,
Yujie Ge,
Lisheng Geng,
Karl Giboni,
Xunan Guo,
Xuyuan Guo,
Zichao Guo,
Chencheng Han,
Ke Han,
Changda He,
Jinrong He,
Houqi Huang,
Junting Huang
, et al. (86 additional authors not shown)
Abstract:
We report a precise measurement of $^{216}\rm Po$ half-life using the PandaX-4T liquid xenon time projection chamber (TPC). $^{220}\rm Rn $, emanating from a $^{228}\rm Th $ calibration source, is injected to the detector and undergoes successive $α$ decays, first to $^{216}\rm Po$ and then to $^{212}\rm Pb$. PandaX-4T detector measures the 5-dimensional (5D) information of each decay, including t…
▽ More
We report a precise measurement of $^{216}\rm Po$ half-life using the PandaX-4T liquid xenon time projection chamber (TPC). $^{220}\rm Rn $, emanating from a $^{228}\rm Th $ calibration source, is injected to the detector and undergoes successive $α$ decays, first to $^{216}\rm Po$ and then to $^{212}\rm Pb$. PandaX-4T detector measures the 5-dimensional (5D) information of each decay, including time, energy, and 3-dimensional positions. Therefore, we can identify the $^{220}\rm Rn $ and $^{216}\rm Po$ decay events and pair them exactly to extract the lifetime of each $^{216}\rm Po$. With a large data set and high-precision $^{220}\rm $Rn-$^{216}\rm $Po pairing technique, we measure the $^{216}\rm Po$ half-life to be $143.7\pm0.5$ ms, which is the most precise result to date and agrees with previously published values. The leading precision of this measurement demonstrates the power of 5D calorimeter and the potential of exact parent-daughter pairing in the xenon TPC.
△ Less
Submitted 17 July, 2025;
originally announced July 2025.
-
First measurement of $Σ^{+}n\rightarrowΛp$ and $Σ^{+}n\rightarrowΣ^{0}p$ cross sections via $Σ^+$-nucleus scattering at an electron-positron collider
Authors:
BESIII Collaboration,
M. Ablikim,
M. N. Achasov,
P. Adlarson,
X. C. Ai,
R. Aliberti,
A. Amoroso,
Q. An,
Y. Bai,
O. Bakina,
Y. Ban,
H. -R. Bao,
V. Batozskaya,
K. Begzsuren,
N. Berger,
M. Berlowski,
M. Bertani,
D. Bettoni,
F. Bianchi,
E. Bianco,
A. Bortone,
I. Boyko,
R. A. Briere,
A. Brueggemann,
H. Cai
, et al. (680 additional authors not shown)
Abstract:
Using $(1.0087\pm0.0044)\times10^{10}$ $J/ψ$ events collected with the BESIII detector at the BEPCII storage ring, the reactions $Σ^{+}n\rightarrowΛp$ and $Σ^{+}n\rightarrowΣ^{0}p$ are studied, where the $Σ^{+}$ baryon is produced in the process $J/ψ\rightarrowΣ^{+}\barΣ^-$ and the neutron is a component of the $^9\rm{Be}$, $^{12}\rm{C}$ and $^{197}\rm{Au}$ nuclei in the beam pipe. Clear signals o…
▽ More
Using $(1.0087\pm0.0044)\times10^{10}$ $J/ψ$ events collected with the BESIII detector at the BEPCII storage ring, the reactions $Σ^{+}n\rightarrowΛp$ and $Σ^{+}n\rightarrowΣ^{0}p$ are studied, where the $Σ^{+}$ baryon is produced in the process $J/ψ\rightarrowΣ^{+}\barΣ^-$ and the neutron is a component of the $^9\rm{Be}$, $^{12}\rm{C}$ and $^{197}\rm{Au}$ nuclei in the beam pipe. Clear signals of these two reactions are observed for the first time. Their cross sections are measured to be $σ(Σ^{+}+{^9\rm{Be}}\rightarrowΛ+p+X)=(45.2\pm12.1_{\rm{stat}}\pm7.2_{\rm{sys}})$ mb and $σ(Σ^{+}+{^9\rm{Be}}\rightarrowΣ^{0}+p+X)=(29.8\pm9.7_{\rm{stat}}\pm6.9_{\rm{sys}})$ mb for a $Σ^{+}$ average momentum of $0.992$ GeV/$c$, within a range of $\pm0.015$ GeV/$c$, where $X$ represents the residual nucleus. This is the first study of $Σ^{+}$-nucleon scattering at an electron-positron collider.
△ Less
Submitted 24 March, 2026; v1 submitted 26 May, 2025;
originally announced May 2025.
-
Pre-study of a Li2MoO4 based bolometer for 100Mo neutrinoless double beta decay experiment in China
Authors:
Deyong Duan,
Mingxuan Xue,
Kangkang Zhao,
Taiyuan Liu,
Haiping Peng,
Jiaxuan Cao,
Long Ma,
Liang Chen,
Hui Yuan,
Qing Lin,
Zizong Xua,
Xiaolian Wang
Abstract:
The cryogenic phonon scintillating bolometer is a promising and extremely attractive option to search for the nuclide neutrinoless double beta decay. In this paper, a pre-study of bolometer based on Li2MoO4 (LMO) crystal is presented, in which the properties of the LMO crystal at the low temperature, including scintillation characteristics and specific heat, are investigated in detail. The excitat…
▽ More
The cryogenic phonon scintillating bolometer is a promising and extremely attractive option to search for the nuclide neutrinoless double beta decay. In this paper, a pre-study of bolometer based on Li2MoO4 (LMO) crystal is presented, in which the properties of the LMO crystal at the low temperature, including scintillation characteristics and specific heat, are investigated in detail. The excitation spectrum and light yield are measured from the room temperature down to 10 K, and heat capacity is measured down to temperature of O(200) mK. Furthermore, a (2 cm)3 cubic LMO based bolometer is manufactured and tested at ultra-low mK-level temperature in a ground-above cryostat platform, and a good energy resolution is achieved. The studies laid a foundation to manufacture the bolometer detector in China and conduct neutrinoless double beta decay research at the China Jinping Underground Laborator
△ Less
Submitted 3 May, 2025;
originally announced May 2025.
-
Search for Double Beta Decay of $^{136}$Xe to the $0^+_1$ Excited State of $^{136}$Ba with PandaX-4T
Authors:
PandaX Collaboration,
Lingyin Luo,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Zhaokan Cheng,
Xiangyi Cui,
Yingji Fang,
Deqing Fang,
Zhixing Gao,
Lisheng Geng,
Karl Giboni,
Xunan Guo,
Xuyuan Guo,
Zichao Guo,
Chencheng Han,
Ke Han,
Changda He,
Jinrong He,
Di Huang,
Houqi Huang,
Junting Huang,
Ruquan Hou,
Yu Hou
, et al. (76 additional authors not shown)
Abstract:
We perform a search of double beta decay of $^{136}$Xe to the excited state, $0^+_1$, of $^{136}$Ba (2$νββ$-0$_1^+$), using the dual-phase xenon detector of PandaX-4T with the first 94.9-day commissioning data. The multi-site events are reconstructed up to the MeV energy scale, which helps to improve the background model significantly. The background contribution from the stainless steel platform…
▽ More
We perform a search of double beta decay of $^{136}$Xe to the excited state, $0^+_1$, of $^{136}$Ba (2$νββ$-0$_1^+$), using the dual-phase xenon detector of PandaX-4T with the first 94.9-day commissioning data. The multi-site events are reconstructed up to the MeV energy scale, which helps to improve the background model significantly. The background contribution from the stainless steel platform outside PandaX-4T cryostat is evaluated for the first time. No significant evidence for 2$νββ$-$0_1^+$ is observed, resulting in a lower limit on half-life of $7.5 \times 10^{22}$ yr at the 90% confidence level. This is the first experimental limit on such a rare decay in a natural xenon-based detector.
△ Less
Submitted 7 March, 2025; v1 submitted 5 February, 2025;
originally announced February 2025.
-
Searching for Neutrinoless Double-Beta Decay of $^{136}$Xe with PandaX-4T
Authors:
PandaX Collaboration,
Shu Zhang,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Zhixing Gao,
Lisheng Geng,
Karl Giboni,
Xunan Guo,
Xuyuan Guo,
Zichao Guo,
Chencheng Han,
Ke Han,
Changda He,
Jinrong He,
Di Huang,
Houqi Huang,
Junting Huang,
Ruquan Hou,
Yu Hou
, et al. (77 additional authors not shown)
Abstract:
We report the search for neutrinoless double-beta decay of $^{136}$Xe from the PandaX-4T experiment with a 3.7-tonne natural xenon target. The data reconstruction and the background modeling are optimized in the MeV energy region. A blind analysis is performed with data from the commissioning run and the first science run. No significant excess of signal over the background is observed. A lower li…
▽ More
We report the search for neutrinoless double-beta decay of $^{136}$Xe from the PandaX-4T experiment with a 3.7-tonne natural xenon target. The data reconstruction and the background modeling are optimized in the MeV energy region. A blind analysis is performed with data from the commissioning run and the first science run. No significant excess of signal over the background is observed. A lower limit on the half-life of $^{136}$Xe neutrinoless double-beta decay is established to be $2.1 \times 10^{24}$~yr at the 90\% confidence level, with a $^{136}$Xe exposure of 44.6~kg$\cdot$year. Our result represents the most stringent constraint from a natural xenon detector to date.
△ Less
Submitted 18 December, 2024;
originally announced December 2024.
-
Measurement of two-neutrino double electron capture half-life of $^{124}$Xe with PandaX-4T
Authors:
PandaX Collaboration,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Zhixing Gao,
Lisheng Geng,
Karl Giboni,
Xunan Guo,
Xuyuan Guo,
Zichao Guo,
Chencheng Han,
Ke Han,
Changda He,
Jinrong He,
Di Huang,
Houqi Huang,
Junting Huang,
Ruquan Hou,
Yu Hou,
Xiangdong Ji
, et al. (77 additional authors not shown)
Abstract:
Detailed studies of two-neutrino double electron capture (2$ν$DEC) is a crucial step towards searching for the neutrino-less mode to explore the Majorana nature of neutrinos. We have measured precisely the half-life of the 2$ν$DEC process in $^{124}$Xe, utilizing a total exposure of 1.73 tonne$\cdot$year from the commissioning run and the first science run of the PandaX-4T experiment. A time-depen…
▽ More
Detailed studies of two-neutrino double electron capture (2$ν$DEC) is a crucial step towards searching for the neutrino-less mode to explore the Majorana nature of neutrinos. We have measured precisely the half-life of the 2$ν$DEC process in $^{124}$Xe, utilizing a total exposure of 1.73 tonne$\cdot$year from the commissioning run and the first science run of the PandaX-4T experiment. A time-dependent background model in the $\mathcal{O}$(10 keV) energy is constructed for the first time in PandaX-4T data. With an unbinned maximum likelihood fit, we determine the half-life of the 2$ν$DEC process to be $(1.03\pm0.15_{\rm stat}\pm0.08_{\rm sys})\times 10^{22}$$\,$yr. Furthermore, we have evaluated the branching ratio for both electrons captured from the $K$ shell ($KK$) to be $(65\pm5)\%$, which aligns with the $^{124}$Xe nuclear model calculations within 1.8$\,$$σ$.
△ Less
Submitted 16 May, 2025; v1 submitted 21 November, 2024;
originally announced November 2024.
-
First Indication of Solar $^8$B Neutrino Flux through Coherent Elastic Neutrino-Nucleus Scattering in PandaX-4T
Authors:
PandaX Collaboration,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Zhaokan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Zhixing Gao,
Lisheng Geng,
Karl Giboni,
Xunan Guo,
Xuyuan Guo,
Zichao Guo,
Chencheng Han,
Ke Han,
Changda He,
Jinrong He,
Di Huang,
Houqi Huang,
Junting Huang,
Ruquan Hou,
Yu Hou,
Xiangdong Ji
, et al. (77 additional authors not shown)
Abstract:
The PandaX-4T liquid xenon detector at the China Jinping Underground Laboratory is used to measure the solar $^8$B neutrino flux by detecting neutrinos through coherent scattering with xenon nuclei. Data samples requiring the coincidence of scintillation and ionization signals (paired), as well as unpaired ionization-only signals (US2), are selected with energy threshold of approximately 1.1 keV (…
▽ More
The PandaX-4T liquid xenon detector at the China Jinping Underground Laboratory is used to measure the solar $^8$B neutrino flux by detecting neutrinos through coherent scattering with xenon nuclei. Data samples requiring the coincidence of scintillation and ionization signals (paired), as well as unpaired ionization-only signals (US2), are selected with energy threshold of approximately 1.1 keV (0.33 keV) nuclear recoil energy. Combining the commissioning run and the first science run of PandaX-4T, a total exposure of 1.20 and 1.04 tonne$\cdot$year are collected for the paired and US2, respectively. After unblinding, 3 and 332 events are observed with an expectation of 2.8$\pm$0.5 and 251$\pm$32 background events, for the paired and US2 data, respectively. A combined analysis yields a best-fit $^8$B neutrino signal of 3.5 (75) events from the paired (US2) data sample, with $\sim$37\% uncertainty, and the background-only hypothesis is disfavored at 2.64$σ$ significance. This gives a solar $^8$B neutrino flux of ($8.4\pm3.1$)$\times$10$^6$ cm$^{-2}$s$^{-1}$, consistent with the standard solar model prediction. It is also the first indication of solar $^8$B neutrino ``fog'' in a dark matter direct detection experiment.
△ Less
Submitted 13 September, 2024; v1 submitted 15 July, 2024;
originally announced July 2024.
-
Searching for Two-Neutrino and Neutrinoless Double Beta Decay of $^{134}$Xe with the PandaX-4T Experiment
Authors:
PandaX Collaboration,
Xiyu Yan,
Zhaokan Cheng,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Chen Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Chencheng Han,
Ke Han,
Changda He,
Jinrong He,
Di Huang,
Yanlin Huang,
Junting Huang,
Zhou Huang
, et al. (72 additional authors not shown)
Abstract:
$^{134}$Xe is a candidate isotope for neutrinoless double beta decay~($0νββ$) search. In addition, the two-neutrino case ($2νββ$) allowed by the Standard Model of particle physics has not yet been observed. Utilizing the 10.4% of $^{134}$Xe in the natural xenon in the PandaX-4T detector and its first 94.9-day exposure, we have established the most stringent constraints on $2νββ$ and $0νββ$ of $^{1…
▽ More
$^{134}$Xe is a candidate isotope for neutrinoless double beta decay~($0νββ$) search. In addition, the two-neutrino case ($2νββ$) allowed by the Standard Model of particle physics has not yet been observed. Utilizing the 10.4% of $^{134}$Xe in the natural xenon in the PandaX-4T detector and its first 94.9-day exposure, we have established the most stringent constraints on $2νββ$ and $0νββ$ of $^{134}$Xe half-lives, with limits of $2.8\times10^{22}$ yr and $3.0\times10^{23}$ yr at 90% confidence level, respectively. The $2νββ$ ($0νββ$) limit surpasses the previously reported best result by a factor of 32 (2.7), highlighting the potential of large monolithic natural xenon detectors.
△ Less
Submitted 28 April, 2024; v1 submitted 25 December, 2023;
originally announced December 2023.
-
Measurement of Double Beta Decay Half-life of $^{136}$Xe with the PandaX-4T Detector
Authors:
PandaX Collaboration,
Lin Si,
Zhaokan Cheng,
Abdusalam Abdukerim,
Zihao Bo,
Wei Chen,
Xun Chen,
Yunhua Chen,
Chen Cheng,
Yunshan Cheng,
Xiangyi Cui,
Yingjie Fan,
Deqing Fang,
Changbo Fu,
Mengting Fu,
Lisheng Geng,
Karl Giboni,
Linhui Gu,
Xuyuan Guo,
Ke Han,
Changda He,
Jinrong He,
Di Huang,
Yanlin Huang,
Zhou Huang
, et al. (63 additional authors not shown)
Abstract:
Precise measurement of two-neutrino double beta decay (DBD) half-life is an important step for the searches of Majorana neutrinos with neutrinoless double beta decay. We report the measurement of DBD half-life of $^{136}$Xe using the PandaX-4T dual-phase Time Projection Chamber (TPC) with 3.7-tonne natural xenon and the first 94.9-day physics data release. The background model in the fiducial volu…
▽ More
Precise measurement of two-neutrino double beta decay (DBD) half-life is an important step for the searches of Majorana neutrinos with neutrinoless double beta decay. We report the measurement of DBD half-life of $^{136}$Xe using the PandaX-4T dual-phase Time Projection Chamber (TPC) with 3.7-tonne natural xenon and the first 94.9-day physics data release. The background model in the fiducial volume is well constrained in situ by events in the outer active region. With a $^{136}$Xe exposure of 15.5 kg-year, we establish the half-life as $2.27 \pm 0.03 (stat.)\pm 0.10 (syst.)\times 10^{21}$ years. This is the first DBD half-life measurement with natural xenon and demonstrates the physics capability of a large-scale liquid xenon TPC in the field of rare event searches.
△ Less
Submitted 12 December, 2022; v1 submitted 25 May, 2022;
originally announced May 2022.
-
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
Authors:
J. Aalbers,
K. Abe,
V. Aerne,
F. Agostini,
S. Ahmed Maouloud,
D. S. Akerib,
D. Yu. Akimov,
J. Akshat,
A. K. Al Musalhi,
F. Alder,
S. K. Alsum,
L. Althueser,
C. S. Amarasinghe,
F. D. Amaro,
A. Ames,
T. J. Anderson,
B. Andrieu,
N. Angelides,
E. Angelino,
J. Angevaare,
V. C. Antochi,
D. Antón Martin,
B. Antunovic,
E. Aprile,
H. M. Araújo
, et al. (572 additional authors not shown)
Abstract:
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut…
▽ More
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector.
△ Less
Submitted 4 March, 2022;
originally announced March 2022.
-
Energy resolution and linearity of XENON1T in the MeV energy range
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
V. C. Antochi,
E. Angelino,
J. Angevaare,
F. Arneodo,
D. Barge,
L. Baudis,
B. Bauermeister,
L. Bellagamba,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon
, et al. (113 additional authors not shown)
Abstract:
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XEN…
▽ More
Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 $σ/μ$ is as low as (0.80$\pm$0.02) % in its one-ton fiducial mass, and for single-site interactions at $Q_{ββ}$. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
△ Less
Submitted 9 September, 2020; v1 submitted 8 March, 2020;
originally announced March 2020.
-
First observation of two-neutrino double electron capture in $^{124}$Xe with XENON1T
Authors:
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
L. Althueser,
F. D. Amaro,
M. Anthony,
V. C. Antochi,
F. Arneodo,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
C. Capelli,
J. M. R. Cardoso,
D. Cichon,
D. Coderre,
A. P. Colijn
, et al. (106 additional authors not shown)
Abstract:
Two-neutrino double electron capture ($2ν$ECEC) is a second-order Weak process with predicted half-lives that surpass the age of the Universe by many orders of magnitude. Until now, indications for $2ν$ECEC decays have only been seen for two isotopes, $^{78}$Kr and $^{130}$Ba, and instruments with very low background levels are needed to detect them directly with high statistical significance. The…
▽ More
Two-neutrino double electron capture ($2ν$ECEC) is a second-order Weak process with predicted half-lives that surpass the age of the Universe by many orders of magnitude. Until now, indications for $2ν$ECEC decays have only been seen for two isotopes, $^{78}$Kr and $^{130}$Ba, and instruments with very low background levels are needed to detect them directly with high statistical significance. The $2ν$ECEC half-life provides an important input for nuclear structure models and its measurement represents a first step in the search for the neutrinoless double electron capture processes ($0ν$ECEC). A detection of the latter would have implications for the nature of the neutrino and give access to the absolute neutrino mass. Here we report on the first direct observation of $2ν$ECEC in $^{124}$Xe with the XENON1T Dark Matter detector. The significance of the signal is $4.4σ$ and the corresponding half-life $T_{1/2}^{2ν\text{ECEC}} = (1.8\pm 0.5_\text{stat}\pm 0.1_\text{sys})\times 10^{22}\;\text{y}$ is the longest ever measured directly. This study demonstrates that the low background and large target mass of xenon-based Dark Matter detectors make them well suited to measuring other rare processes as well, and it highlights the broad physics reach for even larger next-generation experiments.
△ Less
Submitted 24 April, 2019;
originally announced April 2019.
-
Search for Two-Neutrino Double Electron Capture of $^{124}$Xe with XENON100
Authors:
The XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
F. D. Amaro,
M. Anthony,
F. Arneodo,
P. Barrow,
L. Baudis,
B. Bauermeister,
M. L. Benabderrahmane,
T. Berger,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Bütikofer,
J. Calvén,
J. M. R. Cardoso,
M. Cervantes,
D. Cichon,
D. Coderre
, et al. (92 additional authors not shown)
Abstract:
Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For $^{124}$Xe this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K-shell of $^{124}$Xe using 7636 kg$\cdot$d of d…
▽ More
Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For $^{124}$Xe this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K-shell of $^{124}$Xe using 7636 kg$\cdot$d of data from the XENON100 dark matter detector. Using a Bayesian analysis we observed no significant excess above background, leading to a lower 90 % credibility limit on the half-life $T_{1/2}>6.5\times10^{20}$ yr. We also evaluated the sensitivity of the XENON1T experiment, which is currently being commissioned, and find a sensitivity of $T_{1/2}>6.1\times10^{22}$ yr after an exposure of 2 t$\cdot$yr.
△ Less
Submitted 16 February, 2017; v1 submitted 12 September, 2016;
originally announced September 2016.
-
PandaX: A Liquid Xenon Dark Matter Experiment at CJPL
Authors:
X. G. Cao,
X. Chen,
Y. H. Chen,
X. Y. Cui,
D. Q. Fang,
C. B. Fu,
K. L. Giboni,
H. W. Gong,
G. D. Guo,
M. He,
J. Hu,
X. T. Huang,
X. D. Ji,
Y. L. Ju,
S. L. Li,
Q. Lin,
H. X. Liu,
J. L. Liu,
X. Liu,
W. Lorenzon,
Y. G. Ma,
Y. J. Mao,
K. X. Ni,
K. Pushkin,
X. X. Ren
, et al. (25 additional authors not shown)
Abstract:
PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time proj…
▽ More
PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time projection chamber will be staged, with the first stage accommodating a target mass of about 120\,kg. In stage II, the target mass will be increased to about 0.5\,ton. In the final stage, the detector can be upgraded to a multi-ton target mass. In this paper a detailed description of the stage-I detector design and performance results established during the commissioning phase is presented.
△ Less
Submitted 12 May, 2014;
originally announced May 2014.
-
Revisiting the production of charmonium plus a light meson at PANDA
Authors:
Qing-Yong Lin,
Xiang Liu,
Hu-Shan Xu
Abstract:
In this work, we calculate the total cross sections and the center-of-mass frame angular distributions of the charmonium production plus a light meson by the low energy $p\bar{p}$ interaction. The results of $p\bar{p}\to π^0 Ψ$ with and without form factor (FF) indicate that the FF contribution in the calculation cannot be ignored. The obtained cross section of $p\bar{p}\to π^0 J/ψ$ with FF can fi…
▽ More
In this work, we calculate the total cross sections and the center-of-mass frame angular distributions of the charmonium production plus a light meson by the low energy $p\bar{p}$ interaction. The results of $p\bar{p}\to π^0 Ψ$ with and without form factor (FF) indicate that the FF contribution in the calculation cannot be ignored. The obtained cross section of $p\bar{p}\to π^0 J/ψ$ with FF can fit the E760 data well. We also predict the total cross sections and the center-of-mass frame angular distributions of $p\bar{p}\to ωΨ$, which show that these physical quantities are dependent on Pauli ($g_ω$) and Dirac ($κ_ω$) coupling constants of the $ppω$ interaction. Thus, $p\bar{p}\to ωΨ$ can be as the ideal channel to test the different theoretical values of $g_ω$ and $κ_ω$. Applying the formulae of $p\bar{p}\to π^0 Ψ$ and $p\bar{p}\to ωΨ$, we predict the total cross sections of the $p\bar{p}\to ηΨ$ and $p\bar{p}\to ρΨ$ reactions. Our results show a common behavior of the charmonium production with a light meson by the $p\bar{p}$ interaction, where the total cross section of the $η_c$ production is the largest one among all discussed processes. The above observations can be directly tested at the forthcoming $\bar{P}$ANDA experiment.
△ Less
Submitted 27 July, 2012; v1 submitted 18 March, 2012;
originally announced March 2012.